Important News Regarding Rack2-Filer
An issue in importing image data has been verified when creating key text blocks by OCR in Rack2-Filer V5.0. Please apply the following Correction Patch to correct this issue.
March 29, 2013
PFU Limited
Affected Software
Rack2-Filer V5.0 (V5.0L51a, V5.0L52a, V5.0L60a, V5.0L61a, V5.0L62a, V5.0L50, V5.0L51, V5.0L52, V5.0L60, V5.0L61, V5.0L62)
Exclusive Summary
<Issue>
An issue in importing image data has been verified when creating key text blocks by OCR in Rack2-Filer V5.0, where the imported page was replaced by another page.
<Conditions for Occurrence>
- 1) OS
- Windows Vista®
- Windows® 7
- 2) Operations
- The above issue occurs when either of the following operations is performed.
- * Launch Rack2-Viewer, and then create key text blocks by selecting multiple pages
- * Go to [General] of Rack2-Viewer --> Click the [Page Insertion] tab --> Enable [Automatically create key text blocks for inserted pages (by OCR/extraction)] --> Open either [WorkArea] or [Rack2-Viewer] --> Import the text data from the scanner (Note), or import the image data file from the computer
- * Import the image data file by Rack2 Folder Monitor Software
- The above issue occurs when either of the following operations is performed.
Note:
This issue does not occur when you enable "Searchable PDF (OCRs during scan)" in the [File Option] tab and specify [All pages] in "arget pages" in the ScanSnap Manager settings.
Correction Patch
Please apply the following update.
Rack2-Filer V5.0 Service Pack 10 (V5.0L65)